setTimeout(function(){ window.print(); },500)
 

Technical data


Faraday and energetic efficiency of a PEM fuel cell with ADM3

Article no: P9504600

Principle

Fuel cells also have losses, which means that not 100 % of the gases can be converted into electrical energy. In this experiment, the efficiency of the PEM fuel cell is to be determined, and this is to be done in two different ways. In the first part of the experiment, the energetic efficiency is determined, which is a ratio between the energy stored in the gas and the energy that can be used electrically from it, and then the Faraday efficiency is examined, which is a ratio between the real amount of gas consumed and the theoretically calculated value.

Benefits

  • Part of a system solution - easily expandable for further experiments
  • Simple teaching by using the demo board physics
  • Clear test execution by using ADM3 multimeters

Scope of delivery

Connector, straight, module DB 09401-01 1
Connector, angled, module DB 09401-02 4
Connector interrupted, module DB 09401-04 1
Junction, module DB 09401-10 2
Double PEM electrolyser, DB 09488-00 1
Double PEM fuel cell for hydrogen/ oxygen operation and hydrogen/ air operation, DB 09486-00 1
Gas storage tank (30 cm3) H2/O2 06723-01 2
Building Block with magnetic pad, DB 09490-00 2
Metal angle for building block with magnetic pad 09491-00 2
Connector, angled with socket, module DB 09401-12 2
Resistance decade, module DB 09420-00 1
PHYWE Demo Physics board with stand 02150-00 1
PHYWE Power supply, universal, analog display DC: 18 V, 5 A / AC: 15 V, 5 A 13503-93 1
Immersion probe NiCr-Ni, steel, -50...400 °C 13615-03 1
Connecting cable, 32 A, red, various lengths 07361-01 1
Connecting cable, 32 A, blue, various lengths 07361-04 2
Connecting cable, 32 A, yellow, various lengths 07361-02 1
Connecting cable, 32 A, red, various lengths 07362-01 1
Connecting cable, 32 A, yellow, various lengths 07362-02 1
Protecting glasses, clear glass 39316-00 1
PHYWE Demo Multimeter ADM 3: current, voltage, resistance, temperature 13840-00 3
Pinchcock, width 10 mm 43631-10 2
Silicone tubing, various diameters 39292-00 2

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com