setTimeout(function(){ window.print(); },500)
 

Technical data


The characteristic current-voltage curves of a solar cell with ADM3

Article no: P9502700

Principle

The current-voltage characteristic of a solar cell describes its behavior under load. The output power of the solar cell is maximum when its internal resistance is as large as the external resistance. To record the characteristic curve, a resistance decade is connected to the solar cell. It has 12 switch positions, with different resistances (also short-circuit and open), whose values have been selected so that the course of the characteristic curve can be well represented.

Benefits

  • Part of a system solution - easily expandable for further experiments
  • Simple teaching by using the demo board physics
  • Clear test execution by using ADM3 multimeters

Scope of delivery

Connector, angled, module DB 09401-02 4
Connector interrupted, module DB 09401-04 1
Junction, module DB 09401-10 2
Solar cell (2.5x5)cm,module DB 09470-00 1
Resistance decade, module DB 09420-00 1
Clamp on holder 02164-00 1
PHYWE Demo Physics board with stand 02150-00 1
Stand rods, stainless steel, various sizes 02033-00 1
Ceramic lamp socket E27, with reflector, switch and security plug 06751-01 1
Filament lamp, 220V/120W, with reflector 06759-93 1
Connecting cable, 32 A, red, various lengths 07361-01 1
Connecting cable, 32 A, blue, various lengths 07361-04 2
Connecting cable, 32 A, yellow, various lengths 07361-02 1
PHYWE Demo Multimeter ADM 3: current, voltage, resistance, temperature 13840-00 2

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com