setTimeout(function(){ window.print(); },500)
 

Technical data


Hall effect in n- and p-germanium

Article no: P2530116

Principle

The resistivity and Hall voltage of a rectangular germanium sample are measured as a function of temperature and magnetic field. The band spacing, the specific conductivity, the type of charge carrier and the mobility of the charge carriers are determined from the measurements.

Benefits

  • Hall effect unit to control temperature, voltage, and supports intrinsic, p- and n-type Ge crystals
  • Version with PC control and data acquisition
  • Direct connection to PC via USB connection
  • No extra interface necessary
  • Magnetic field sensor can be connected directly with the Hall effect unit

Tasks

  1. The Hall voltage is measured at room temperature and constant magnetic field as a function of the control current and plotted on a graph (measurement without compensation for defect voltage).
  2. The voltage across the sample is measured at room temperature and constant control current as a function of the magnetic induction B.
  3. The voltage across the sample is measured at constant control current as a function of the temperature. The band spacing of germanium is calculated from the measurements.
  4. The Hall voltage UH is measured as a function of the magnetic induction B, at room temperature. The sign of the charge carriers and the Hall constant RH together with the Hall mobility μH and the carrier concentration p are calculated from the measurements.
  5. The Hall voltage UH is measured as a function of temperature at constant magnetic induction B and the values are plotted on a graph.

Learning objectives

  • Semiconductor
  • Band theory
  • Forbidden zone
  • Intrinsic conductivity
  • Extrinsic conductivity
  • Valence band
  • Conduction band
  • Lorentz force
  • Magnetic resistance
  • Mobility
  • Conductivity
  • Band spacing
  • Hall coefficient

 Software included. Computer not provided.

Scope of delivery

PHYWE Hall-effect unit HU 2 11801-01 1
measureLAB, multi-user license 14580-61 1
Hall effect, p-Ge, carrier board 11805-01 1
Hall effect, n-Ge, carrier board 11802-01 1
Coil, 600 turns 06514-01 2
Iron core, U-shaped, laminated 06501-00 1
Pair of pole pieces, plane, 30 x 30 x 48 mm 06489-00 1
Hall probe, tangential, protection cap 13610-02 1
PHYWE Power supply, 230 V, DC: 0...12 V, 2 A / AC: 6 V, 12 V, 5 A 13506-93 1
Tripod base PHYWE 02002-55 1
Stand rods, stainless steel, various sizes 02031-00 1
Right angle clamp expert with fulcrum screw 02054-00 1
Connecting cable, 32 A, red, various lengths 07361-01 2
Connecting cable, 32 A, blue, various lengths 07361-04 1
Connecting cable, 32 A, black, various lengths 07362-05 2

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com