Technical data


Earthing of the power supply line

Article no: P1377300

Principle

Fatal accidents can occur when electrical appliances are handled in a household. Most of such accidents result from careless behaviour or lack of knowledge. The person model is to be used to demonstrate which parts of an electric circuit are extremely dangerous to touch.
Power is supplied to a household via an L-lead connected to the supply voltage and an earthed N-lead. The earthing of the N-lead is necessary to produce a steady potential against earth (important when lightning strikes or insulation is faulty). The earthing of the N-lead is associated with dangers, however, as an electric circuit can then be closed to earth. This experiment demonstrates when there is danger because of the earthing of the N-lead and how such danger can be avoided.

Benefits

  • No additional cable connections between the building blocks needed - clear arragned and quick setup
  • Contact saftey due to puzzle blocks system
  • Corrosion-free gold plated contacts
  • Doubled earning sucess: Electric circuit diagram on top, real components can be seen unterside

Tasks

Which dangers are associated with electric current?

Set up an electric circuit with a safety fuse, switch and filament lamp. In a power supply network there is an L-lead and an earthed N-lead. Use the person model to examine the dangers which are associated with electric current and with the earthing of the N-lead.

 

Scope of delivery

Straight connector module, SB 05601-01 4
Angled connector module, SB 05601-02 2
T-shaped connector module, SB 05601-03 1
Interrupted connector module with sockets, SB 05601-04 2
Junction module, SB 05601-10 2
Straight connector module with socket, SB 05601-11 1
Angled connector module with socket, SB 05601-12 2
On-off switch module, SB 05602-01 1
Socket module for incandescent lamp E10, SB 05604-00 1
Resistor module 10 kOhm, SB 05615-10 1
Resistor module 47 kOhm, SB 05615-47 1
Alligator clips, bare, 10 pcs 07274-03 1
Connecting plug, 2 pcs. 07278-05 1
Connecting cable, 32 A, red, various lengths 07360-01 1
Connecting cable, 32 A, blue, various lengths 07360-04 2
Connecting cable, 32 A, red, various lengths 07361-01 1
Connecting cable, 32 A, blue, various lengths 07361-04 2
Filament lamps 12V/0.1A, E10, 10 pieces 07505-03 1
Iron wire, d = 0.2 mm, l = 100 m 06104-00 1
PHYWE Power supply, 230 V, DC: 0...12 V, 2 A / AC: 6 V, 12 V, 5 A 13506-93 1

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10 – 37079 Göttingen – Germany
www.phywe.com